UFx.py version 1.6 from 07/16/2018
Page 1 of 2
Created by user vjeran on 07/17/2018 14:35:48
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_upstream\Final Results\Stretched Wire |
Date : | 06-29-2018 |
Time : | 13:55:22 - 14:59:47 |
Operator : | VV |
Project : | LCLS-II |
Device Type : | Phase Shifter |
Run Number : | 1 |
Data Type : | |
Run Comment : | 126 Gauss*cm magnet, +By, upstream pos |
gap | I1Y | I2Y | I1X | I2X |
- |
110.1 0.7 (5) |
38.0 0.3 (3) |
3.9 0.8 (5) |
1.3 0.1 (5) |
integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
I1Y |
- |
105.9 1.7 (3) |
109.1 0.2 (3) |
106.9 2.4 (3) |
108.9 0.4 (3) |
108.6 0.9 (3) |
I2Y |
- |
37.8 0.2 (3) |
37.5 0.4 (3) |
37.5 0.4 (3) |
37.8 0.2 (3) |
37.5 0.4 (3) |
I1X |
- |
3.6 1.0 (2) |
4.0 0.5 (3) |
3.6 1.1 (2) |
3.4 0.7 (3) |
3.8 0.8 (3) |
I2X |
- |
0.9 0.5 (3) |
1.1 0.4 (3) |
1.0 0.6 (3) |
1.2 0.4 (3) |
0.7 0.5 (3) |
integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
I1Y |
- |
109.1 0.8 (3) |
108.8 0.4 (3) |
108.9 0.6 (3) |
109.4 1.4 (3) |
109.0 0.4 (3) |
I2Y |
- |
38.1 0.2 (3) |
37.9 0.3 (3) |
38.0 0.3 (3) |
38.0 0.2 (3) |
37.9 0.3 (3) |
I1X |
- |
3.2 0.5 (3) |
0.6 0.9 (3) |
2.1 1.7 (3) |
2.1 2.5 (3) |
1.2 2.0 (3) |
I2X |
- |
1.2 0.4 (3) |
0.5 0.2 (3) |
0.9 0.7 (3) |
0.6 0.1 (3) |
0.8 0.7 (3) |
UFx.py version 1.6 from 07/16/2018
Page 2 of 2
Created by user vjeran on 07/17/2018 14:35:48
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_upstream\Final Results\Stretched Wire |